Tuesday, July 21, 2009

instrumental methods in spice industry

INSTRUMENTATION

1.SPECTROPHOTOMETER:

1. CURCUMIN (Colour value)

PROCEDURE:

Weigh 0.2 gram turmeric powder in a 250 ml. RB flask, Add 75 ml acetone. Cover the RBF with aluminium foil paper to prevent light absorption. Reflux for 1 hour in a mantle using water condenser at 10oC. Then cotton filter to a 250 ml. dark standard flask and make up with acetone. Then bowl pipette 5 ml to 50 ml standard flask and make up using acetone.

The Curcumin content is detected by spectrophotometer it contains two quvettes, one for acetone and one for solution which is used to make up the solution. The wave length of Curcumin is 420 nm. Adjust to that wave length and make the reading to 0. Then find the value of solution.

CALCULATION:

Absorbance x dilution factor

Factor derived from Curcumin standard x wt. of sample taken

2. PIPERINE (Pepper)

PROCEDURE:

Take 0.5 gm. Sample in 250ml RBF. Add 70 ml SDA No.3A denatured alcohol. (i.e. 20: 1 - ethanol: methanol solution) the flask is covered with aluminium foil. Reflex for one hour at 20oC allow cooling to room temperature and making upto 250 ml. Use extraordinary filter paper and 250 ml amber colour std. flask. From this solution pipette 2 ml and make upto 50 ml. It is filled in cuvette and kept in spectrophotometer and the reading is noted at the wavelength of 342 nm.

CACULATION:

Absorbance x dilution factor

Std. of Piperine x weight of sample

3. CAPSANTHIN (Colour value)

PROCEDURE:

Accurately weigh 1 gm of ground chilly sample into a 100 ml volumetric flask. Add 75 ml extra pure acetone into this flask. Keep this inside a dark cupboard for 16 hours or overnight to allow the particles to settle. Take 5 ml into 100 ml volumetric flask. Make up with acetone and transfer a portion of the extract using Millipore and pour into quvette and keep in spectrophotometer and measure the absorbance (A) at 460 nm with acetone.

CALCULATION:

Absorbance x 60.4 x 10

Weight of sample taken

2.CHROMATOGRAPHY

OPERATION:

The sample to be analyzed is introduced in small volume to the stream of mobile phase. The analyte's motion through the column is slowed by specific chemical or physical interactions with the stationary phase as it traverses the length of the column. The amount of retardation depends on the nature of the analyte, stationary phase and mobile phase composition. The time at which a specific analyte elutes (comes out of the end of the column) is called the retention time; the retention time under particular conditions is considered a reasonably unique identifying characteristic of a given analyte. The use of smaller particle size column packing (which creates higher backpressure) increases the linear velocity (speed) giving the components less time to diffuse within the column, leading to improved resolution in the resulting chromatogram. Common solvents used include any miscible combination of water or various organic liquids (the most common are methanol and acetonitrile). Water may contain buffers or salts to assist in the separation of the analyte components, or compounds such as trifluoroacetic acid which acts as an ion pairing agent.

1. AFLATOXIN (CHILLY)

INSTRUMENT CONFIGRATION:

· Shimadzu HPLC with following configuration

· Liquid chromatograph pump

· Fluorescent detector

· Rheodine injector

· c- 18 250 mm 170 Armstrong silica column

· CMB- 20 alite system controller

· Data processor- LC solution

INSTRUMENT CONDITION:

· Mobile phase flow rate: 1.2 ml/min

· Total run time : 20 min

· Temperature : 250C

MOBILE PHASE:

· Ethanol: Water (45:55)

AIM:

To detect the presence of Aflatoxin in chilly

PROCEDURE:

Take 25 gm sample and 5 gm sample into the blending jar. Add 100 ml 80% methanol. This is blended for 80 sec, filtered through fluted filter paper. From this solution 100 ml passes through immuno affinity column. 20 ml water washing, elute with 1ml methanol. This is collected in cuvette (1 ml). This colour solution is injected in HPLC and a graph is obtained which shows the absence or presence of Aflatoxin.

2. CAPSAICIN (Pungency)

INSTRUMENT CONDITION:

· Mobile phase flow rate: 1 ml/min

· Total run time : 20 min

· Temperature : 250C

MOBILE PHASE:

· Acetonitrile: Water: Acetic acid

AIM:

To find the percentage of capsaicin in chilly powders

PROCEDURE:

Take 12.5 gm of chilly powder into a RBF and add 100 ml alcohol. Reflux for 3 hours in multimantle. Cool at room temperature. Filter it using whattmann No.1 filter paper, and then using Millipore. It is a device which has two kinds of filters. Collect the sample and inject through the inject port system.

3. SUDAN DYE (Adulteration)

INSTRUMENT CONFIGRATION:

· Shimadzu HPLC with following configuration:

· Liquid chromatograph pump

· UV-Visible detector

· Rheodine injector

· SCL-10 A VP system controller

· C- 18 250 nm 100 Armstrong 5 micron silican column

· Data processor- LC solution

INSTRUMENT CONDITION:

· Mobile phase flow rate: 1 ml/min

· Total run time : 20 min

· Temperature : 250C

MOBILE PHASE:

· Acetonitrile: Water (95:5)

· Water: Acetic acid (100:16.5)

AIM:

To detect the presence of Sudan dye on chilly

PROCEDURE:

Take 10 gm sample into 250 ml conical flask then add 100 ml CH3CN. This solution is stirred for 1 hour using magnetic stirrer. Then filter through whattmann No.1 filter paper from this solution pipette 5 ml make up to 50 ml using acetonitrile. Then it Millipore filtered. Take this sample and inject into the HPLC. A graph is obtained which shows the absence or presence of Sudan dye.

GAS CHROMATOGRAPHY

Gas-liquid chromatography (GLC), or simply gas chromatography (GC), is a type of chromatography in which the mobile phase is a carrier gas, usually an inert gas such as helium or an unreactive gas such as nitrogen, and the stationary phase is a microscopic layer of liquid or polymer on an inert solid support, inside glass or metal tubing, called a column. The instrument used to perform gas chromatographic separations is called a gas chromatograph (also: aerograph, gas separator).

Gas Chromatography is different from other forms of chromatography (HPLC, TLC, etc.) because the solutions travel through the column in a gas state. The interactions of these gaseous analyte with the walls of the column (coated by different stationary phases) causes different compounds to elute at different times called retention time. The comparison of these retention times is the analytical power of GC. This makes it very similar to high performance liquid chromatography.

GC analysis

A gas chromatograph is a chemical analysis instrument for separating chemicals in a complex sample. A gas chromatograph uses a flow-through narrow tube known as the column, through which different chemical constituents of a sample pass in a gas stream (carrier gas, mobile phase) at different rates depending on their various chemical and physical properties and their interaction with a specific column filling, called the stationary phase. As the chemicals exit the end of the column, they are detected and identified electronically. The function of the stationary phase in the column is to separate different components, causing each one to exit the column at a different time (retention time). Other parameters that can be used to alter the order or time of retention are the carrier gas flow rate, and the temperature.

In a GC analysis, a known volume of gaseous or liquid analyte is injected into the "entrance" (head) of the column, usually using a micro syringe (or, solid phase micro extraction fibers, or a gas source switching system). As the carrier gas sweeps the analyte molecules through the column, this motion is inhibited by the adsorption of the analyte molecules either onto the column walls or onto packing materials in the column. The rate at which the molecules progress along the column depends on the strength of adsorption, which in turn depends on the type of molecule and on the stationary phase materials. Since each type of molecule has a different rate of progression, the various components of the analyte mixture are separated as they progress along the column and reach the end of the column at different times (retention time). A detector is used to monitor the outlet stream from the column; thus, the time at which each component reaches the outlet and the amount of that component can be determined. Generally, substances are identified (qualitatively) by the order in which they emerge (elute) from the column and by the retention time of the analyte in the column.

chemical tests in spice industry

CHEMICAL ANALYSIS

There are different chemical tests done for different products. The main Chemical test done are Ash, acid insoluble ash, non-volatile ethyl extract moisture, water insoluble ash, alkalinity of soluble ash aqueous extract, crude fiber, (Fineness, Extraneous matter insect damage, Bulk density pinheads, Light berries Tendrils, mother cloves, khoker cloves, headless cloves) caffeine, metanil yellow, Lead chromate (damaged grains, wievelled grains, other edible grains).

1. MOISTURE:

Take 3gm of sample in moisture analyzer moisture content is automatically read in the instrument. Manually moisture can be determined by Toluene method.

2. TOTAL ASH:

Ash is the mineral content of the sample weight 2 gm of sample in crucible and kept in oven. It become ash and calculates the percentage.

PURPOSE:

To determine the ash content of the given sample

SCOPE:

Powders of chilly, coriander, turmeric, black pepper.

APPARATUS:

Flat bottomed crucible with a capacity of 10-25ml electrical muffle furnace, with indicating pyrometer and automatic thermo regulator desiccators containing and efficient desiccant such as an anhydrous copper sulfate or silica gel.

Reagents : Distilled water

PROCEDURE:

Ignite the flat bottomed dish or crucible to dull redness cool to room temperature desiccators and weigh use sample under preparation of sample. Weigh accurately 2-3gms well mixed samples in tarred flat bottomed dish or crucible. Weigh the dish or crucible in the entrance of the open muffle furnace until the sample is well carbonized. The sample must not catch fire.

Place the carbonized sample in the furnace at 600+20°C for 2 hours. Check for the presence of carbon for this cool the dish crucible to room temperature of wet the wash with several drops of distilled water. If carbon particles are seen, dry the dish and ashing. Repeat wetting and heating until no particles of carbon are visible and ignite in the muffle furnace for this after the disappearance of carbon remains wash ash with hot water and ignite in the muffle at 1000+20°C until the ash is white, cool in a desiccators and weight.

CALCULATIONS:

Total ash percent by = Weight of ash in Gms × 100

Weight of sample in Gms

3. ACID INSOLUBLE ASH:

PURPOSE:

To determine the acid insoluble ash

SCOPE:

All mixed curry powders, chilly powders, turmeric powder and black pepper Powder.

REAGENTS:

HCL solutions 1: 2: 5 (dilution) 100ml of Concentrated HCL with 250 ml of distilled water.

APPARATUS:

Funnel, water glass, silica crucible, muffle furnace , filter paper.

PROCEDURE:

Use total ash obtained on total ash determination. To this added 5-10 ml of the HCL solution and filter and cover the dish to a watch glass to prevent scattering. Filter through ash less filter Paper. Wash the filter paper with hot water until washing, are free from HCL acid, as Tested by silver nitrate solution, and Return to the dish. Evaporate carefully on the Water bath and ignite in the muffle furnace at 550 ±25 20° for 1 hour. Cool the dish in desiccators and weigh. Repeat the Operations of igniting for 1 hour, cooling and wetting till the difference in the mass between two successive weighing is less than 0.001 g. Note the lowest mass.

CALCULATION:

Acid insoluble ash percent by mass = (M4 –M0) × 100 ×100 – H

M1-M0

Where,

M4 - Mass in gm of the dish

M0 - Mass in gm of the empty dish

M1 - Mass in gm of the dish and test portion

H - Moisture content of the sample as received

4. ALKALINITY OF SOLUBLE ASH:

PROCEDURE:

The filtrate obtained in water soluble ash is titrated against 0.In Hcl solution using methyl orange as indicator.

CALCULATION:

For Tea = 4.7 x V x N

(M1 –M)

V= Volume of STD HCL used

N= Normality of HCL

M1= Mass in gm of crucible + material

M= Mass of crucible empty

5. AQUEOUS EXTRACT:

This test is carried out to detect the solubility of coffee

To determine this:

1. 2g sample is taken in a condensing flask

2. 100ml distilled water is added

3. Condense for 1 hr with air condenser at 300C

4. Make up to 250 ml

5. Filter through am ordinary filter paper

6. Weigh through an ordinary filter paper

7. Weigh a small beaker

8. Take 50 ml of filtrate in this beaker

9. Dry the beaker in 1000C & cool & weight

CALCULATION:

% of aqueous extract = Weight difference x 250

50

Sample wt

6. VOLATILE OIL:

Take 50g sample in 1000ml R.B flask. Add 500ml of water. Connect it with a Clevenger trap apparatus and condenser. Fill the trap with water. Heat the condense of the flask over a heating mantle. Collect the volatile oil in the trap continue the boiling till oil collecting the trap ceases. Take the reading of the volatile oil and calculate the percent of volatile oil.

CALCULATION

Volume of Oil in ml

Volatile oil =

Wt of sample

7. CRUDE FIBRE:

REAGENTS:

· Petroleum ether

· Dilute H2SO4 - 1.25%

· NaOH - 1.25%

· Ethanol - 95%

PROCEDURE:

1) Weigh 2.5 g of the ground material into a thimble.

2) Extract for about 1 hour with petroleum ether using soxhlet apparatus.

3) Transfer the material to a 1 litre flask.

4) Take 200ml of the dilute Hcl in a beaker and boil.

5) Transfer the whole of the boiling acid to the flask and immediately connect with a water-cooled reflux condenser.

6) Continue boiling for 30 minutes.

7) Remove the flask and filter through fine linen.

8) Bring some quantity of NaOH solution to boil under a reflux condenser.

9) Wash the residue on the filter into the flask with 200ml of boiling NaOH solution.

10) Immediately connect the flask with the reflux condenser and boil for extract 30 minutes.

11) Remove the flask and immediately filter through the linen.

12) Thoroughly wash the residue with boiling water and transfer to a Gooch crucible prepared with a thin but compact layer of ignited asbestos.

13) Wash the residue first with hot water and then wash with ethanol and with three successive washings of 15 ml of petroleum ether.

14) Dry the Gooch crucible at 105±1°c in an air oven for 3 hours, cool and weigh.

15) Repeat the drying process for 30 minutes.

16) Incinerate the contents of the Gooch crucible in the muffle furnace at 550±20°c until all the carbonaceous matter is burnt.

17) Cool the Gooch crucible containing the ash in a desiccators and weigh.

CALCULATION:

Crude fiber (on dry basis) percent by mass = 100(M1-M2)×100

M×100-H

Where,

M1 = mass in g of Gooch crucible and contents before ashing

M2 = mass in g of Gooch crucible containing asbestos and ash.

M = mass in g of the material taken for the test

H = moisture content of the sample as received in percent.

8. NON VOLATILE ETHER EXTRACT:

PROCEDURE:

Take 2g well mixed sample in a paper and put it in thimble. Thimble is kept in round bottom flask. Add 150ml petroleum ether and kept in soxhlet apparatus. Reflux for 18hrs at 400 – 600c.

CALCULATION:

NVEE = 100 ( M1-M2)

M

Where, M1 - Mass in gm of flask with non volatile ether extract

M2 - Mass in gm of flask with non volatile ether extract

after decantation

M - Mass in g of the material taken in the test

9. COLD WATER EXTRACT:

Cold water extract is used to find the solubility.

PROCEDURE:

Take 2g sample. Make up to 100ml. Shake it at every half an hour kept overnight. Take 50ml of this without shaking in a pre weighed beaker. Reflux for 1 hour and weight is taken.

ADULTERATION TESTS

a) METANIL YELLOW:


Concentrated HCL is added in to sample. Violet color appears. Add distilled water into it. The Violet color changes to yellow. This indicates the absence of metanil yellow.

B) LEAD CHROMATE:

Ash 2gm sample. 1: 7ml H2504 is added to 5ml ethanol and 0.1 g biphenyl carboside mixture. This mixture is added to the ash. Presence of purple colour indicates the presence of lead chromate.